CASE STUDIES

OXIDATION CATALYSTS FOR CO-GENERATION PLANT

Manuli Film, Naples, Italy, with three (3) Rolls Royce KVGS-18G2, lean burn, natural gas engines, each 3030 kW electrical. Thermal power is utilized both from exhaust gas and cooling water for plastic film production.

CHALLENGE

Required to meet emission standard of 400 mg/Nm3 @ 5% O2 for carbon monoxide and 150 mg/Nm3 @ 5% O2 non-methane hydrocarbons.

SOLUTION

DCL supplied three (3) reactor housings containing catalyst elements with dimensions 556 x 581 x 92 mm, capable of being individually loaded by hand.The units were installed in 1998 and operated for over five years before the replacement of catalyst elements was necessary.

Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.